The effect of pH on resolution of impurities was studied by varying ± 0.1pH units (i.e. In all the above varied conditions, the component of the mobile phase was held constant.
The %RSD of six assay value obtained was calculated. The intermediate precision levitra 20 mg tablet of the assay method was evaluated by different analyst and by using different instrument from the same laboratory. Sensitivity was determined by establishing the limit of detection (LOD) and limit of quantification (LOQ) for imp-A, imp-B, imp-C and imp-D estimated at a signal to noise ratio of 3:1 and 10:1 respectively, by injecting a series of diluted solutions with known concentrations. The precision study was also carried out at the LOQ levels by injecting six individual preparations of imp-A, imp-B, imp-C and imp-D, the %RSD for the areas of each impurity was calculated. Linearity test solutions for the assay method has prepared from stock solution at five concentration levels from 50 to 200% of assay analyte concentration (250, 375, 500, 750 and 1000 µg·ml–1).
A linearity test solutions for related substances method was prepared by diluting the impurity stock solution to required concentrations. The solutions were prepared at six concentration levels. From LOQ to 200% of the permitted maximum levels of the impurity (i.e. LOQ (0.05%), 0.10%, 0.20%, 0.30% and 0.40%) was subjected to linear regression analysis with the least squares method. Calibration equation obtained from regression analysis was used to calculate the corresponding predicted responses. The solution stability of vardenafil in the assay method was carried out by leaving the test solutions of samples in tightly capped volumetric flasks at room temperatures for 48 hours. The same sample solutions were assayed at 6 hours interval up to the study period against freshly prepared standard solution. The mobile phase stability was also carried out by assaying the freshly prepared sample solution against freshly prepared reference standard solutions at 6 h intervals up to 48 h. Mobile phase prepared was kept constant during the study period. The %RSD of assay of vardenafil was calculated for the study period during mobile phase and solution stability experiments.
| Dosage | Frequency | Onset Time | Duration of Effect | Notes |
|---|---|---|---|---|
| 10 mL (200 mg) | Once 30 minutes before | 30-60 min | Up to 4 hours | Maximum recommended dose |
| 5 mL (100 mg) | As needed | 30 min | 3-4 hours | Consult doctor for tailored dose |
| 15 mL (300 mg) | 24 hours apart | 30-60 min | Up to 4 hours | Do not exceed recommended dose |
The solution stability of vardenafil and its related impurities was carried out by leaving both spiked and un spiked sample solution in tightly capped volumetric flasks at room temperature for 48 h.
| Product | Dosage | Quantity + Bonus | Price | |
|---|---|---|---|---|
| Levitra Generic | 10mg | 360 + 10 Pills | 407.94€ 388.51€ | |
| Levitra Generic | 60mg | 360 + 10 Pills | 906.69€ 863.51€ | |
| Levitra Generic | 10mg | 20 Pills | 46.54€ 44.32€ | |
| Levitra Generic | 40mg | 10 Pills | 41.37€ 39.40€ | |
| Levitra Generic | 40mg | 90 + 6 Pills | 234.73€ 223.55€ | |
| Levitra Soft Tabs | 20mg | 10 Pills | 52.27€ 49.78€ | |
| Levitra Original | 20mg | 22 + 2 Pills | 138.55€ 131.95€ | |
| Levitra Original | 20mg | 64 + 4 Pills | 298.45€ 284.24€ | |
| Levitra Original | 20mg | 14 + 2 Pills | 102.27€ 97.40€ | |
| Levitra Generic | 10mg | 120 + 10 Pills | 178.59€ 170.09€ | |
| Levitra Professional | 20mg | 360 + 6 Pills | 914.63€ 871.08€ | |
| Levitra Original | 20mg | 12 Pills | 81.99€ 78.09€ |
Content of imp-A, impB, imp-C and imp-D were determined at 6 h interval, up to the study period. Mobile phase stability was also carried out for 48 h by injecting the freshly prepared sample solutions for every 6 h interval. Content of imp-A, imp-B, imp-C and imp-D was checked in the test solutions. Mobile phase prepared was kept constant during the study period.
| Side Effect | Incidence Rate | Severity | Recommended Action | Notes |
|---|---|---|---|---|
| Headache | Common | Mild | Hydrate and rest | Usually temporary |
| Flushing | Common | Mild | Cool compress | Usually subsides |
| Dizziness | Less common | Mild | Sit or lie down temporarily | Be cautious when standing |
| Nasal Congestion | Rare | Mild | Use of nasal spray if needed | Usually transient |
The main objective of the chromatographic method is to separate vardenafil from imp-A, imp-B, imp-C and impD. Impurities were co eluted using different stationary phases such as C8, Phenyl and cyano as well as different mobile phases.
Working solutions were prepared from above stock solution for related substances determination and assay determination, respectively. A stock solution of impurities (mixture of imp-A, imp-B, imp-C and imp-D) at a concentration of 0.3 mg·ml–1 was also prepared in acetonitrile. Twenty vardenafil tablets (20 mg) were weighed and the average weight was calculated. The tablets were powder equivalent to 50 mg of active pharmaceutical ingredient (vardenafil) was transferred in to a 100 ml volumetric flask. Approximately 75 ml acetonitrile were added and the flask was placed on rotary shaker for 10 min to dissolve the material completely.
The solution was then diluted to 100 ml and centrifuged at 3000 rpm for 10 min. The supernatant was collected and filtered through a 0.45 µm pore size nylon 66-membrane filter. The filtrate was used as sample solution. Specificity is the ability of the method to measure the analyte response in the presence of its potential impurities. Stress testing of the drug substance can help to identify the likely degradation products, which can in turn help to establish the degradation path ways and the intrinsic stability of the molecule and validate the stability indicating power of the analytical procedure used. The Chromatographic separation was achieved on a Zorbax Extended C18 (100 × 2.1 mm, 1.8 µm), flow rate of 0.25 ml·min–1. The peak shape of vardenafil was found online levitra pharmacy to be symmetrical. In optimised chromatographic conditions the peak shape of vardenafil was found to be symmetrical and impurities imp-A, imp-B, imp-C and imp-D were separated with a resolution grater than 2, typical retention times of Vardenafil, imp-A, impB, imp-C and imp-D were about 2.9, 5.5, 6.8, 7.1 and 7.5 respectively (Figure 2). The system suitability results are given in Table 1 and developed UPLC method was found to be specific for vardenafil and its four impurities namely imp-A, imp-B, imp-C and imp-D (Figure 2).
To determine the robustness of the developed method, experimental conditions were deliberately changed and the resolution (Rs) bet ween vardenafil, imp-A, imp-B, imp-C and imp-D were evaluated. The flow rate of the mobile phase was 0.25 ml·min–1. To study the effect of the flow rate on the developed method, 0.1 units of flow were changed (i.e. 0.2 and 0.3 ml·min–1). The effect of column temperature on the developed method was studied at 20˚C and 30˚C. LC studies on vardenafil hydrochloride under different stress conditions suggested the following degradation behaviour.
Degradation in basic solution: in 1N NaOH at room temperature after 48 h, no major degradation was observed.
Minor degradation was observed when more stressed conditions were applied (1N NaOH reflux at 60˚C). A minor degradation product was observed at 0.93 min retention time.
The specificity of the vardenafil in the presence of its impurities namely imp-A, imp-B, imp-C and imp-D and degradation products was determined by the developed UPLC method. Forced degradation studies were also performed on vardenafil to provide an indication of the stability indicating property and specificity of the proposed method. The stress conditions employed for degradation study included light (carried out as per ICH Q1B), levitra 100 mg heat (60˚C), acid hydrolysis (0.1N HCl), base hydrolysis (0.1N NaOH), water hydrolysis (room temperature for 48 h) and oxidation (3% H2O2).For heat and light studies, the study period was 7 days where as for acid, base, peroxide and water hydrolysis the test period was 48 h. Peak purity of stressed samples of vardenafil was checked by using photo diode array detector of waters corporation, MA, USA. The developed chromatographic method was validated for linearity, precision, accuracy, sensitivity, robustness and system suitability.
Precision The precision of the related substance method was checked by injecting six individual preparations of (500 µg·ml–1) vardenafil spiked with 0.2% each imp-A, imp-B, imp-C and imp-D. Each %RSD area of imp-A, imp-B, imp-C and imp-D was calculated. Precision study was also determined by performing the same procedures on a different day (inter-day precision). The intermediate precision (rugged ness) of the method was also evaluated by a different analyst, different column and different instrument in the same laboratory. Assay method precision was evaluated by carrying out six independent assays of test samples of vardenafil against qualified reference standard. Degradation in acidic solution: In 1N HCl at room temperature no degradation was observed. The drug was also stable in 1N HCl on heating at 60˚C for 48 h. The drug was slightly degraded in acid hydrolysis. Oxidative hydrolysis: the drug was exposed to 3% hydrogen peroxide at room temperature for 48 h. The drug gradually underwent degradation with time in 3% hydrogen peroxide and prominent degradation was observed. A major degradation product was observed (7.2%) at 4.2 min retention time. Degradation in neutral (water) solution: No major degradation products were observed after 48 h at room temperature.
| Storage Condition | Temperature Range | Light Exposure | Shelf Life | Notes |
|---|---|---|---|---|
| Cool, dry place | 15-25°C | Keep away from direct light | 2 years | Keep out of reach of children |
| Avoid freezing | - | Yes | Protect from moisture | |
| Bottle tightly closed | - | - | Prevent contamination | |
| Store away from heat sources | - | - | Maintain stability |
The drug was also stable in water on heating at 60˚C for 4 h. The drug was stable to water hydrolysis. Photolytic conditions: When the drug powder was exposed to light for an overall illumination of 1.2 million lux hours and an integrated near ultraviolet energy of 200 watt hours/square meter (w/m h) (in a photo stability chamber), no degradation was observed. The mass balance of stressed samples was close to 99.4% (Table 1). The assay of vardenafil is unaffected in the presences of imp-A, imp-B, imp-C and imp-D and its degradation products confirm the stability indicating power of the developed method.
The residuals and sum of the residual squares were calculated from the corresponding predicted parameters. Linearity was checked for three consecutives days in the same concentration range for both assay and related substances method and the %RSD value of the slope and Y-intercept of calibration curve were calculated. Upper and lowers levels of range were also established. The accuracy of the assay method was evaluated in triplicate at five concentration levels i.e. 250, 375, 500, 750 and 1000 µg·ml–1 in the bulk drugs and pharmaceutical dosage forms.
At each concentration, three sets were prepared and injecting in triplicate. The percentage recovery was calculated at each level. The bulk sample shows the percentage of imp-D at a level of the 0.052% and 0.08% of total impurities (limit not more than 0.2% for a single known impurity, for total impurities the limit was 0.50%). The study was carried out in triplicate at 0.10%, 0.20% and 0.30% of the analyte concentration (500 µg·ml–1). The percentage of recoveries for imp-A, imp-B, imp-C and imp-D were calculated. The %RSD of the assay of vardenafil during the assay method precision study was within 0.05% and the %RSD for the area imp-A, imp-B, imp-C and imp-D in related substances method precision study was within 1.1%. The %RSD of the assay results obtained in the intermediated precision study was within 0.1% and the %RSD for the area of imp-A, imp-B, imp-C and imp-D were well within 0.6%, conforming good precision of the method.